Vidikron VP-42 Computer Monitor User Manual


 
98
External Controls
37 FACTORY
Function
The external control equipment resets the user adjustment of the plasma monitor.
Transmission Data
1FH 80H 60H 54H 00H CKS
ACK
3FH 60H 80H 54H 00H CKS
38 AUDIO SELECT SET
Function
The external control equipment sets combinations of audio and video inputs for the
plasma monitor.
Transmission Data
DFH 80H 60H 70H 02H DATA00 DATA01 CKS
DATA00: AUDIO 01H: AUDIO 1
02H: AUDIO 2
03H: AUDIO 3
DATA01: VISUAL INPUT 01H: Video 1
02H: Video 2
03H: Video 3
05H: HD (HD1 or DVD or DVD1)
06H: HD2 (DTV2)
07H: RGB 1/PC1
08H: RGB 2/PC2
0CH: RGB 3/PC3
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 70H 00H CKS
* The plasma monitor returns “Not Available” when selecting the video input same as the
one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or
VIDEO3 after VIDEO1 has been set to AUDIO1.