Vidikron VP-42 Computer Monitor User Manual


 
87
14 RED GAIN DATA
Function
The external control equipment changes the RED gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: RED Gain Flag 01H
DATA02: RED Gain 1 (Offset) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA03 RED Gain 2 (Drive) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: RED Gain Flag 01H
15 GREEN GAIN DATA
Function
The external control equipment changes the GREEN gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: GREEN Gain Flag 02H
DATA02: GREEN Gain 1 (Offset) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA03 GREEN Gain 2 (Drive) D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: GREEN Gain Flag 02H
External Controls