Xantrex Technology XFR 2800 Power Supply User Manual


 
Features and Specifications
Rear Panel Connectors and Switch
Release 2.1 23
Table 1.3 Rear Panel J2 Connector Terminals and Functions
Connector Reference Name Function
J2-1 VRMT Remote Output Voltage
Programming Select
Selects remote output voltage
programming when jumpered to pin 3.
J2-2 IRMT Remote Output Current Limit
Programming Select
Selects remote output current limit
programming when jumpered to pin 3.
J2-3 CNTL GND Control Ground Control ground.
J2-4 N/C No connection None.
J2-5 VPGM– Voltage Program Signal Return Return for voltage program signal.
J2-6 VPGM Output Voltage Programming
Input
Input for voltage programming signals
from an analog device.
J2-7 IPGM– Current Program Signal Return Return for current program signal.
J2-8 IPGM Output Current Limit
Programming Input
Input for current limit programming
signals from an analog device.
J2-9 VMON– Voltage Monitor Signal Return Return for voltage monitor signal.
J2-10 VMON Output Voltage Monitor Output for output voltage monitor signal.
J2-11 IMON– Current Monitor Signal Return Return for current monitor signal.
J2-12 IMON Output Current Monitor Output for output current monitor signal.
J2-13 N/C No connection None.
J2-14 S/D– Shutdown Signal Return (–) Return for shutdown signal.
J2-15 S/D S/D Input (+) Input for shutdown signal.