Xantrex Technology XFR 2800 Power Supply User Manual


 
Local Operation
Standard Operation
60 Operating Manual for XFR 2.8kW Series Power Supply
Setting
Output
Voltage and
Current Limit
Install the power supply and connect the load as described in Section 2. Installation.
Ensure that the power supply is set up for local control as described in “Shipped
Configuration (Local Control Mode)” on page 59. Then, set the output voltage and
current limit at the front panel with the following procedure.
1. Turn both the voltage and current controls fully counter-clockwise.
2. Turn the AC power ON.
3. Press the STANDBY switch to its IN position to disable the power supply
output. The red Shutdown (S/D) LED turns on.
4. Press and hold the V/I CHECK button to display the voltage and current control
settings on the voltmeter and ammeter displays.
5. Adjust the voltage control to the desired voltage (the compliance voltage for
applications using current mode operation).
6. Adjust the current control to the desired current limit setting.
7. Release the V/I CHECK button.
8. Press the STANDBY switch to its OUT position to apply power to the load. The
S/D LED turns off.
Note:The control circuits have been designed to allow you to set output voltage and
current up to 5% over the model-rated maximum values. The power supply will
operate within these extended ranges, but we cannot guarantee full performance to
specification.