Xerox 2060 Copier User Manual


 
Defining the printer to the host: TCP/IP attachment
F-14 Installation Planning Guide
NOTE: It is not necessary to define the printer in TCP/IP for
MVS, because the printer acts as a conduit from the MVS
system to the LAN. However, some settings in the TCP/IP Profile
dataset may need to be altered, depending on your current
settings.
Table F-7. TCP/IP Profile dataset parameters – MVS
Item description Default
Source of
value
Range of
acceptable
values Comments
Your
value
DATABUFFERPOOLS
IZE
Data buffers
160 Installation
preferences
7 to nnnn, where
nnnn is limited by
available virtual
storage
Specify at least
160 buffers.
DATABUFFERPOOLS
IZE
Buffer size
16384 Installation
preferences
8192 49152
12288 65536
16384 98304
24576 131072
28672 196608
32768 262144
Specify a buffer
size of at least
32768, if possible.
SMALLDATABUFFER
POOLSIZE
0 Installation
preferences
0 to nnnn, where
nnnn is limited by
available virtual
storage
Specify at least
256 small data
buffers.
TINYDATABUFFERP
OOLSIZE
0 Installation
preferences
0 to nnnn, where
nnnn is limited by
available virtual
storage
Specify at least
256 tiny data
buffers.
KEEPALIVEOPTIONS Interval
120
sendgarba
ge false
Installation
preferences
See Notes.
GATEWAY
max_packet_size
Defaultsize
is 576
Installation
preferences
Can be from 576
to 67108864, but
cannot be larger
than value
specified on
LARGEENVE
LOPEPOOLSIZE
statement.
Max packet size
parameter should
be no greater than
4472 bytes in a 4
Mbps LAN
configuration, and
17800 in a 16
Mbps LAN
configuration.
Default MTU value