Zebra Technologies 2237A10L010 Label Maker User Manual


 
Data Ports
Applicator Interface Connector
184
13383L-004 Rev. A XiIIIPlus/R110Xi/R170Xi User Guide 9/6/07
5 PAUSE Input To toggle the current Pause state, this input must be
asserted LOW for 200 milliseconds, or until the
SERVICE REQUIRED output (pin 10) changes state.
6 REPRINT Input If the Reprint feature is enabled, this input must be
asserted LOW to cause the printer to reprint the last
label.
If the Reprint feature is disabled, this input is ignored.
7+28V
(For the 5V board,
+28V is fused at 2 A.
For the 24–28V
board, +28V is fused
at 500 mA.)
Caution • Replace
the fuse only with
one of the same
type and rating.
Power The Interface Power Supply. Supplies power to external
sensors as required.
Note • If operating with 28V signals only, pin 7
may be used to supply power to pin 2, which
creates a non-isolated mode of operation. (This is
applicable for all printers except the
110XiIIIPlus.)
8 POWER GROUND
(+28 V DC Return)
Ground The Interface Power Ground.
Note • If pin 7 is used to supply power to pin 2,
use this pin to ground pin 1. (This is applicable for
all printers except the 110XiIIIPlus.)
9 No function.
10 SERVICE
REQUIRED
Output Asserted LOW in the following circumstances:
the printhead is open
the ribbon or media is out
the printer is paused
an operational fault occurs
a Resynch error occurs while the applicator Resynch
mode is set to Error mode (see Select Resynch Mode
on page 96)
Table 22 • Applicator Interface Connector Pin Configuration (Continued)
Pin
No.
Signal Name Signal Type Description
* Applicator boards have separate part numbers for the +5V version (49872-099M) and the +24-28V version (33361-099M).