Zebra Technologies 2237A10L010 Label Maker User Manual


 
59
Operations
Adjust Media Sensors
9/6/07 XiIIIPlus/R110Xi/R170Xi User Guide 13383L-004 Rev. A
4. Using the tip of the screwdriver, slide the upper sensor along the slot to the desired
position (for non-continuous media with a notch or hole in the media, the sensor must be
directly above the notch or hole).
5. Tighten the adjustment screw to secure the upper media sensor.
Upper Media Sensor—Outside Half of Media
To adjust the upper media sensor for the outside half of the media, complete
these steps (all models except the 220XiIIIPlus):
1. Remove the ribbon (if ribbon is used).
2. See Figure 12. Locate the upper media sensor. The upper media sensor eye is directly
below the adjustment screw head.
3. Using a Phillips-head screwdriver, remove the upper media sensor adjustment screw.
4. Lift the upper media sensor assembly from the slot, and move it and the wire cover to the
outside slot. Carefully pull the wires through the cable tie. You may need to set aside the
sensor wire cover if the adjustment is too far to the outside.
5. Replace and slightly tighten the adjustment screw.
6. Slide the upper media sensor along the slot to the desired position (for non-continuous
media with a notch or hole in the media, the sensor must be directly above the notch or
hole).
7. Tighten the adjustment screw.
8. Make sure that the wires are routed back into the groove of the media sensor bracket.