Zebra Technologies S4M Printer User Manual


 
81
Configuration
Control Panel Parameters
6/15/09 S4M User Guide 13290L-004 Rev. A
DELIM. CHAR
(ZPL mode only)
Set Delimiter Character
The delimiter character is a two-digit hexadecimal value used as a
parameter place marker in ZPL/ZPL II format instructions. See the ZPL II
Programming Guide for more information.
Note • Do not use the same hexadecimal value for the control,
command, and delimiter character. The printer must see different
characters to work properly.
Range: 00 to FF
Default Value: 2C (comma)
To modify this parameter:
To increase the value, press the up arrow.
To decrease the value, press the down arrow.
HEXDUMP
Hex Dump
The hexadecimal dump mode is a troubleshooting tool for checking the
interconnection between the printer and the host computer. For more
information, see Communications Diagnostics Test on page 121.
Selections: NO, YES
Default Value: NO
To modify this parameter:
Press the up or down arrow to scroll through the selections.
REPRINT MODE
(ZPL mode only)
Reprint Mode
When Reprint Mode is enabled, the
~PR ZPL command can be used to
reprint the last label. If the Reprint feature is disabled, the
~PR command
is ignored. (Equivalent to the reprint mode parameter in the
^JJ ZPL
command.)
Selections: ENABLED, DISABLED
Default Value: DISABLED
CHANGE RTC DATE
Set RTC (Real-time clock) Date
If RTC is installed, this parameter allows you to set the RTC date.
Note • The printer saves the RTC date immediately.
To modify this parameter:
1. Press ENTER.
The printer displays the current RTC date.
2. Modify the values as follows:
Press the right arrow to move to the next digit position.
To increase the value, press the up arrow.
To decrease the value, press the down arrow.
3. Press ENTER to accept the value shown.
Table 15 • Printer Parameters, Password Level 3 (Page 5 of 10)
Parameter Explanation