ZyXEL Communications ZyWALL5UTM 4.0 Network Router User Manual


 
ZyWALL 5/35/70 Series User’s Guide
Appendix S Log Descriptions 786
11 Time Exceeded
0 Time to live exceeded in transit
1 Fragment reassembly time exceeded
12 Parameter Problem
0 Pointer indicates the error
13 Timestamp
0 Timestamp request message
14 Timestamp Reply
0 Timestamp reply message
15 Information Request
0 Information request message
16 Information Reply
0 Information reply message
Table 295 IDP Logs
LOG MESSAGE DESCRIPTION
The buffer size is
too small!
The buffer for holding IDP information such as the signature file version
was too small to hold any more information.
The format of the
user config file is
incorrect!
There was a format error in the configuration backup file that someone
attempted to load into the system.
The system is doing
signature update
now , please wait!
The device is updating the signature file.
No data! The system could not find any IDP signatures that matched a search.
IDP %s! The device detected an intrusion event in a connection. The format of %s is
“ID” followed by the IDP ID signature number and the IDP signature name.
For example, ID:10001,Window Ping.
Can not find the
signature , please
update the
signature!
The device does not have a signature file loaded.
Failed in signature
update - %s!
The device failed to update the signature file through the Internet. %s
describes the reason for the error. You may need to provide the error
message when contacting customer support if you are repeatedly unable to
download the signature file from the update server.
Check signature
version - %s.
The device attempted to check for the latest available signature version.
%s gives details. Either the check was unsuccessful due to the server
being busy or the device is already using the latest available firmware.
Table 294 ICMP Notes (continued)
TYPE CODE DESCRIPTION