1 Battery cable
2 Remote battery cable connector
3 Battery
4 Battery carrier
5 Battery connector
6. Disconnect the battery cable from the battery cable connector on the battery
carrier.
7. Remove the three screws that attaches the battery carrier to the battery and
remove the battery from the battery carrier.
Note: If your battery 1 and battery carrier 2 are attached with a clip,
squeeze the clip on the side of the battery carrier to remove the battery from the
battery carrier.
If you are instructed to return the RAID adapter battery, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to you.
Installing a RAID adapter remotely in the server
When you install any RAID adapter that come with batteries in the PCI slot 1 and
PCI slot 2, it is sometimes necessary to install the batteries in another location in
the server to prevent the batteries from overheating. The batteries must be installed
only on top of the microprocessor 2 air baffle. To install the RAID adapter battery in
the server, complete the following steps:
1. Read the safety information in “Safety” on page vii and “Installation guidelines”
on page 39.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see “Removing and replacing the cover” on page 43).
4. Route the remote battery cable through the notches on the microprocessor 2 air
baffle.
Attention: Make sure that the cable is not pinched and does not cover any
connectors or obstruct any components on the system board.
5. Install the battery on the microprocessor 2 air baffle:
106 ThinkServer RD210 Types 3795, 3796, 3818, and 3819: Installation and User Guide