Installing the microprocessor 2 air baffle
To install the microprocessor 2 air baffle (if you removed it), complete the following
steps:
1. Read the safety information in “Safety” on page vii and “Installation guidelines”
on page 39.
2. Turn off the server and peripheral devices and disconnect the power cords and
all external cables, if necessary.
3. Align the microprocessor 2 air baffle tab with the hole on the side of the
power-supply cage; then insert the tab into the hole on the cage (make sure
that the front end of the air baffle is lined up with the blue press point tab on the
left of fan 6). Press the air baffle down until the it is securely seated.
4. Install the cover see “Removing and replacing the cover” on page 43).
5. Reconnect the power cords and any cables that you removed.
6. Turn on the peripheral devices and the server.
Removing and installing the DIMM air baffle
To remove and install the DIMM air baffle, complete the steps in this section.
Removing the DIMM air baffle
To remove the DIMM air baffle, complete the following steps:
1. Read the safety information in “Safety” on page vii and “Installation guidelines”
on page 39.
2. Turn off the server and peripheral devices and disconnect the power cords and
all external cables.
Note:
When you disconnect the power source from the server, you will lose the
ability to view the LEDs because the LEDs will not be lit with the power source
removed. Before disconnecting the power source, make a note of which LEDs
are lit, including the LEDs that are lit on the operation information panel, the
EasyLED panel, and LEDs that are lit inside the server on the system board;
then, see the Hardware Maintenance Manual for information on how to solve
the problem.