EasyLED diagnostics panel
The EasyLED diagnostics panel is located on the top of the operator information
panel.
Note:
The system service label on the underside of the cover also provides
information about the location of the EasyLED.
To access the EasyLED diagnostics panel, slide the blue release button on the
operator information panel to the left. Pull forward on the unit until the hinge of the
operator panel is free of the server chassis. Then pull down on the unit, so that you
can view the EasyLED panel information.
Note:
When you slide the EasyLED diagnostics panel out of the server to check
the LEDs or checkpoint codes, do not run the server continuously with EasyLED
diagnostics panel outside of the server. The panel should only be outside of the
server a short time. The EasyLED panel must remain in the server when the server
is running to ensure proper cooling.
1 Release latch
2 EasyLEDs
3 Operator information panel
The following illustration shows the LEDs and controls on the EasyLED panel.
v Remind button:This button places the system-error LED on the front panel into
Remind mode. In Remind mode, the system-error LED flashes rapidly until the
problem is corrected, the system is restarted, or a new problem occurs.
Chapter 4. Server controls, LEDs, and power 17