4. Touch the static-protective package that contains the new ServeRAID-BR10i
SAS/SATA controller to any unpainted surface on the outside of the server; then,
grasp the adapter by the top edge or upper corners of the controller and remove
it from the package.
5. Align the ServeRAID-BR10i SAS/SATA controller so that the keys align correctly
with the connector on the SAS/SATA RAID riser card assembly.
1 USB embedded connector
2 RAID controller connector
3 Riser card error LED
4 SAS/SATA RAID riser card
6. Insert the SAS/SATA controller 2 into the connector on the SAS/SATA RAID
riser card assembly 1 until it is firmly seated.
Attention: Incomplete insertion might cause damage to the server or the
controller.
7. Tilt the SAS/SATA RAID riser-card assembly slightly and insert the end of the
adapter in the slot on the retention bracket as shown in the following illustration.
Make sure that the SAS/SATA RAID riser-card assembly keys align correctly
with the connector on the system board and press down on the assembly until it
is seated firmly into the connector on the system board.
66 ThinkServer RD210 Types 3795, 3796, 3818, and 3819: Installation and User Guide