3. If the server has been installed in a rack, slide the server out from the rack
enclosure. See the Rack Installation Instructions that come with the server for
information about removing the server from the rack.
4. Press down firmly on the two blue tabs on the top (near the front of the server)
of the cover and slide the cover toward the rear of the server until the cover has
disengaged from the chassis.
5. Lift the server cover off the server and set it aside.
Replacing the cover
Attention: For proper cooling and airflow, replace the server cover before you
turn on the server.
To replace the server cover, complete the following steps:
1. Align the cover 1 over the server (toward the rear of the server) until the
cover edges slip in position over the chassis.
2. Press down on the two blue tabs 2 and 3 on the front of the cover, while
sliding the cover forward toward the front of the server until the cover is
completely closed.
Internal cable routing and connectors
The following illustration shows the internal routing and connectors for the two SAS
signal cables (in server models with eight SAS drive bays).
Notes:
1. To connect the SAS signal cables, make sure that you first connect the signal
cable, and then the power cable and signal cable.
2. To disconnect the SAS signal cables, make sure that you first disconnect the
power cable, and then the signal cable and configuration cable.
44 ThinkServer RD210 Types 3795, 3796, 3818, and 3819: Installation and User Guide