3Com 6416SW Network Card User Manual


 
ATM Subsystem Chassis Management
Management of the ATM subsystem can be achieved in two ways:
Via a Distributed Management Module (DMM) installed in the ONcore hub.
Via the 6416SW module, which contains a subset of DMM, when the ONcore hub is
only running ATM. (Check the Release Notes for the level of 6416SW code
required).
Note: If a DMM module is present, or hot-inserted, in the hub, the DMM module will
assume chassis management, and 6416SW commands entered will not be effected.
The required commands, in this case, should be entered from a DMM console, and not
the local console.
Power management of the hub is provided by the SET POWER MODE and SHOW
POWER commands. The power mode can be set so that if an additional power supply
is available, the supply is kept in reserve, to be used in the event of failure. Power
management information can be displayed to show the amount of power available, and
the amount of power consumed by the hub. In addition, the power budget, power
modes, and power information can be displayed for individual slots.
A complete inventory of the hub's contents, including fans and power supplies can be
displayed via the SHOW HUB command.
The SHOW INVENTORY command allows you to display inventory information about
the hub, including all modules, submodules, and controller module.
For more information, see the
ONcore Switching Hub/CELLplex 4000 ATM Command
Reference Guide
.
1-12 ONcore ATM Switch/Control Module: Installation and User's Guide