3Com 6416SW Network Card User Manual


 
Verifying Normal 6416SW Operation
After installing the 6416SW module, you can verify that it is operating properly by
checking the status of the LEDs and the message displayed on the console screen.
The position of the LEDs is shown in Figure 2-4 on page 2-9.
The RUNNING LED on the module should light (yellow).
The ACTIVE LED should light (yellow) if the 6416SW module is managing ATM
media modules.
The WRONG SLOT LED should not light.
If the module is installed properly and if the RS-232 connection is made, the
following message should display on the console screen when you press Enter:
ATM Switch/Control Module
(c) Copyright IBM Corp. 1994, 1996. All rights reserved.
Now you can enter 6416SW commands from the local console to set up your system
defaults and configure ATM media modules as explained in Chapter 5, “Configuring the
ATM Switch/Control Module” on page 5-1. If you have problems while configuring your
ATM subsystem, refer to Chapter 7, “Troubleshooting” on page 7-1.
How to perform wrap tests on ATM ports is described in the
ONcore Switching
Hub/CELLplex 4000 ATM Command Reference Guide
.
The next section describes the front panel of the 6416SW module and the meaning of
each LED.
2-7