Procedures
3-36 ATP-CNX-040-01 Rel. 1.3, Doc. Rev. 01.07
CNX System Administrator Guide
6
(cont’d)
H.323 attributes continued.
7 Click to save the configuration to the Aastra CNX and to the CompactFlash card.
Step Action
Attribute Default Valid Values/Description
Gatekeeper Address
Note: Enabled only if
Gatekeeper
Registration is set to
ENABLE.
0.0.0.0 Description: The IP address of the Gatekeeper in the
network.
User Authentication
Note: Enabled only if
Gatekeeper
Registration is set to
ENABLE.
DISABLE ENABLE
DISABLE
Description: Specifies whether or not authentication
is enabled or disabled on the Aastra CNX.
Authentication is the process of verifying whether a
user is allowed access to the Aastra CNX using the
H.323 protocol over a LAN, WAN, or over the Internet.
Gatekeeper
Password
Note: Enabled only if
User Authentication is
set to ENABLE.
***** Description: Specifies the password that the
Aastra CNX uses to gain access to the H.323
gatekeeper.
Port
Note: Enabled only if
Gatekeeper
Registration is set to
ENABLE.
1720 1024 to 64000
Description: Specifies the User Datagram Protocol
(UDP) port on the Aastra CNX that listens for and
receives/processes H.323 messages.