Chapter 1 23
NOTE: DC-AC inverter is used to generate very high AC voltage, then support to LCD CCFT backlight user,
and is also responsible for the control of LCD brightness. Avoid touching the DC-AC inverter area while
the system unit is turned on.
NOTE: There is an EEPROM in the inverter, which stores its supported LCD type and ID code. If you replace
a new inverter or replace the LCD with a different brand, use Inverter ID utility to update the ID
information.
DC-AC LCD Inverter
Item Specification
Vendor & model
name
Ambit T621124.00 730
Input voltage (V) 7.3 (min.) - 21 (max.)
Input current (mA) - - 900 (max.)
Output voltage
(Vrms, no load)
-565 (typ.)-
Output voltage
frequency (kHz)
40 (min.) - 65 (max.)
Output Current/
Lamp
Iout(Min) 0.7mA 1.0mA 1.3mA Vadj=0V
Iout(Max) 6.3mA 7.0mA 7.7mA Vadj=3.2V
LCD
Item Specification
Vendor & model name Hitachi
TX38D95VC1CAM
Mechanical Specifications
LCD display area (diagonal, inch) 15
Display technology TFT
Resolution SXGA+ (1400x1050)
Supports colors 262K
Optical Specification
Brightness control keyboard hotkey
Contrast control No
Electrical Specification
Supply voltage for LCD display (V) 3.3
Supply voltage for LCD backlight
(Vrms)
690
AC Adapter
Item Specification
Vendor & model name Delta ADT-60XB D 3P
Input Requirements
Maximum input current (A,
@90Vac, full load)
1.5 A @ 90Vac
0.9 A @ 180Vac
Nominal frequency (Hz) 47 - 63
Frequency variation range (Hz) 47 - 63
Nominal voltages (Vrms) 90 - 270
Inrush current The maximum inrush current will be less than 50A and 100A when the adapter
is connected to 115Vac(60Hz) and 230Vac(50Hz) respectively.