Acer Altos G710 Personal Computer User Manual


 
Appendix C: SCSI RAID configuration
160
If you change the settings in the Hot Spare field, the following
messages appear:
WARNING: Data on drive will be LOST!
Press DELETE if data loss OK or any other key to
cancel.
6 Press the Delete key to ignore.
7Press Esc, then select Save changes then exit this menu.
8 To close the utility and reboot the server, follow the steps below:
(1) Press Esc, then select Exit the Configuration Utility.
The Global properties saved. Hit any key to
reboot message appears.
(2) Press any key to reboot the server.
RAID volume initialization
After you create the RAID volume and saved the changes, the disk
controller will automatically initialize the RAID volume. LSI Logic
53C1030 supports background initialization, there’s no need to wait
for the initialization to complete. Close the LSI Logic Configuration
Utility after saving the changes.
Using the MegaRAID configuration utility
Turn on the system. When prompted, press Ctrl+M to enter the
MegaRAID configuration utility. After a few seconds, the Management
menu appears.
Loading the RAID card default setting
1 In the Management menu, select Objects, then select Adapter.
The current adapter settings appear.
2Select Factory Default, then Yes to load the default settings.
3Press Ctrl+Alt+Del to reboot the server.