ADTRAN 1240 Network Router User Manual


 
Total Access 1240 Installation and Maintenance Practice
5-76 61179605L5-5B
SHDSL Loop 1 LineProbing Menu
The SHDSL Loop 1 LineProbing menu (see Figure 5-56) is used to configure the Total Access
1240 line probe feature which performs a sequence of power measurements on the twisted
pair. From these measurements, the Total Access 1240 determines what the maximum line
rate is that it can connect at.
Another name for line probe is Power Measurement Modulation Session (PMMS). This session
is performed during the handshake or pre-activation phase of the G.SHDSL training
sequence. Once the line probe session is finished, the units will immediately attempt to train.
Figure 5-56. SHDSL Loop 1 LineProbing Menu
The SHDSL Loop 1 LineProbing menu options are shown in
Table 5-55. SHDSL Loop 1 LineProbing Menu Options
Option Description Function
1 Disabled Line probing is disabled.
2 Enabled - Current Condition Current Condition specifies that the line probing
sequence should determine the maximum rate it can
run given the current conditions on the line at the time
of measurement.
3 Enabled - Worst Case
Condition
Worst Case Condition specifies that the line probing
sequence should assume that worst case conditions
exist on the line and then determine the maximum rate
at which to run.
09/01/05 02:21
Total Access 1240
SHDSL Loop 1 LineProbing
1. Disabled
2. Enabled - Current Condition
3. Enabled - Worst Case Condition
Selection:
'?' - System Help