ADTRAN 1240 Network Router User Manual


 
Section 5, User Interface - Menu Descriptions
61179605L5-5B 5-57
External Alarms Menu
The External Alarms menu (see Figure 5-39) is used to customize the profiles for up to three
external alarms. The alarms can be assigned unique names and an associated severity level
(refer to “External Alarm Severity Menu” on page 5-58).
Figure 5-39. External Alarms Menu
The External Alarms menu options are shown in Table 5-41.
Table 5-41. External Alarms Menu Options
Option Description Function
1 Alarm #1 Text This option is used to enter a 25-character text string for
Alarm #1.
2 Alarm #2 Text This option is used to enter a 25-character text string for
Alarm #2.
3 Alarm #3 Text This option is used to enter a 25-character text string for
Alarm #3.
4 - 6 Severity Options 4 to 6 are used to assign severity levels to each
of the three external alarms. For more information, refer
to “External Alarm Severity Menu” on page 5-58.
7 Fan Alarm Delay This option is used to set the delay for amount of time it
takes for an alarm to be generated when the fan module
is removed. This alarm can be set between 0–15
minutes.
Total Access 1240 - IPoE Fed
Unacknowledged Alarms: None
External Alarms
1. Alarm #1 Text - External Alarm Input #1 4. Severity - Minor
2. Alarm #2 Text - External Alarm Input #2 5. Severity - Minor
3. Alarm #3 Text - External Alarm Input #3 6. Severity - Minor
7. Fan Alarm Delay Disabled
Selection :
'?' - System Help Screen