Chapter 6: Connecting Accessories
Half-channel Adapter (E5386A)
Half-channel Adapter (E5386A)
NOTE: For use with Agilent 16760A logic analyzers.
The E5386A Half-channel Adapter is intended to be used in half-channel state mode
and works with:
E5378A 100-pin Single-ended Probe
E5379A 100-pin Differential Probe
E5387A Differential Soft Touch Probe
E5390A Single-ended Soft Touch Probe
The E5386A Half-channel Adapter has it’s own ID code. When using the adapter,
the logic analyzer recognizes its code rather than that of the probe which is attached
to the target. Therefore, the user interface format menu doesn’t automatically set
thresholds to the right values. You need to go into the threshold menu and select
(differential, custom, or standard settings).