Agilent Technologies J3972A Network Router User Manual


 
Local Terminal Configuration
Using a Local Terminal
33
OC-3 ATM Interface Configuration
You must configure two of the three ports on the probe’s OC-3 ATM interface.
The third port cannot be configured. Use the following procedure to configure
items in the Modify/View Interface Values menu for the first port on the OC-3
ATM interface:
1. Press
3
to access the
Modify/View interface values
menu item. The
Modify/View Interface Values menu for port 1 is displayed, as shown in
Figure 2-7.
Figure 2-7: Modify/View Interface Values Menu (OC-3 ATM, Port 1)
2. Select each field requiring configuration (one at a time) by pressing its
corresponding number and then entering the values that are appropriate for
your network.
Port Press
1
and then enter the OC-3 ATM interface’s port number
to display the OC-3 ATM port’s configuration parameters
along with their current settings. Refer to “Display Interface
Summary” on page 36 for information on port types and port
numbers for the installed interfaces. You can then view or
configure the OC-3 ATM port’s configuration parameters.
Port Type Press
2
and select the port type as Monitor-only.
Modify/View Interface Values Menu - Firmware Rev
Interface Type STS3C/STM1
1. Port 3.1/STS3C-STM1
2. Port Type Monitor-only
3. Cell Sychronization HEC
4. Cell Scrambling On
S. Save changes and exit
0. Cancel changes and exit