Alcatel Carrier Internetworking Solutions 6648 Switch User Manual


 
Troubleshooting Switched Ethernet Connectivity Verify Switch Health
OmniSwitch Troubleshooting Guide September 2005 page 2-7
Verify Switch Health
If source learning appears to be not working correctly, verify the health of the switch with the show health,
and show health slot commands. Be sure to run the latter command on all necessary NIs. Any variables
that have reached or exceeded their limit value could cause forwarding problems on the switch. In this
case please contact Technical Support. For more detailed source learning trouble shooting, please see
Chapter 3, “Troubleshooting Source Learning.”
-> show health
* - current value exceeds threshold
Device 1 Min 1 Hr 1 Hr
Resources Limit Curr Avg Avg Max
-----------------+-------+------+------+-----+----
Receive 80 00 00 00 00
Transmit/Receive 80 00 00 00 00
Memory 80 39 39 39 39
Cpu 80 02 02 02 03
Temperature Cmm 50 39 39 39 39
Temperature Cmm Cpu 50 31 31 31 31
-> show health 5
* - current value exceeds threshold
Slot 05 1 Min 1 Hr 1 Hr
Resources Limit Curr Avg Avg Max
-----------------+-------+------+------+-----+----
Receive 80 00 00 00 01
Transmit/Receive 80 01 01 01 01
Memory 80 16 16 16 16
Cpu 80 29 33 32 35
Verify ARP
If everything checked appears to be valid, verify that this is not an ARP problem. On the end stations
involved, enter a static mac address for the device it is trying to communicate with. If connectivity is
restored, please see Chapter 11, “Troubleshooting ARP.”