Allied Telesis X610-24TS-POE+ Switch User Manual


 
Configuring AMF
Page 20 | How to Configure and Use AMF on Allied Telesis Switches
across CFCs. If an AT-x908 VCStack is configured as an AMF master, a licence is required to
be installed on bothstack members.
AMF_Master(config)#vlan database
AMF_Master(config-vlan)#vlan 2-3
AMF_Master (config)#no spanning-tree rstp enable
AMF_Master(config)#int port1.1.1-1.1.2
AMF_Master(config-if)#switchport atmf-link
AMF_Master (config-if)#switchport trunk allowed vlan add 2-3
AMF_Master #copy running-config startup-config
Building configuration...[OK]
AMF_Master#reload
Are you sure you want to reboot the whole chassis? (y/n): y
Configuration Member1
awplus#conf t
awplus(config)#hostname Member1
Host names must be unique within the AMF network.
Member1(config)#atmf network-name atmf1
Note:
The AMF network name must be the same on all nodes within the AMF network, and
the device must be rebooted before the AMF network name takes effect.
Member1(config)#vlan database
Member1(config-vlan)#vlan 2-3
Member1(config)#no spanning-tree rstp enable
4. Configure the data VLANs.
5. Disable RSTP globally (this is enabled by default).
6. Configure ports as AMF-links.
7. Configure data VLANs on AMF-links as required.
8. Save the configuration and reboot the switch.
1. Set the host name.
2. Set the AMF network name.
3. Configure data VLANs.
4. Disable RSTP globally (this is enabled by default).