American Power Conversion S20BLK Power Supply User Manual


 
2-16
OUTLET DELAY1 and OUTLET DELAY2 — These settings let you set a defined
time delay (0 to 10 seconds) for when the unit provides power to the rear panel
outlet marked Switched Delayed1 (TUNER/AUX), or Switched Delayed2
(SUBWOOFER and/or AMPLIFIER). By setting this delay it prevents power on or
power off glitches from affecting other equipment connected to the unit. Outlet
Delay1 is shown in Figure 33; the Outlet Delay2 screen is not shown.
Figure 33. Outlet Delay1 Setting Screen
LOWBATTWARNING: XMIN Setting — This screen, shown in Figure 34, lets
you set the unit to sound an alarm, and illuminate the LOWBATTWARNING LED
whenever the battery pack’s estimated runtime remaining drops to or below the
programmed setting (2 to 26 minutes).
Figure 34. LOWBATTWARNING Setting Screen
BATREPDATE: XX/XX/XX Setting — This function allows you to input the exact
date a replacement battery pack is installed in the unit, as shown in Figure 35. First,
use the Up/Down Arrow pushbuttons to set the correct month, then press the
SETUP pushbutton to move the cursor to the day of the month field. Set the day of
the month using the Up/Down Arrow pushbuttons. Press the SETUP pushbutton to
move the cursor to the year field. Set the year using the Up/Down Arrow buttons.
Figure 35. BATREPDATE: XX/XX/XX Setting Screen
DO QUIK SELFTEST Setting — This function lets you manually initiate a
self-test to ensure that the battery pack is in good health, and the unit is operating
properly.
Note: When you advance to this screen, press the Up/Down Arrow pushbuttons
to start the Selftest. During Selftest, the same screens that were
previously defined in this manual, are displayed.
OUTPUT DELAY1: 5 SEC
PRESS ↑ ↓ TO CHANGE
LOWBATWARNING:2MIN
PRESS ↑ ↓ TO CHANGE
BATREPDATE:10-10-06
PRESS ↑ ↓ TO CHANGE