Avocent 3100/3200 Personal Computer User Manual


 
Appendices 69
Appendix B: Using AVRIQ-SRL modules
The AVRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to
be viewed from the AutoView 3100/3200 switch local port or by using the on-board web interface.
The actual serial data is not accessed, but is merely displayed. All serial data coming from the
target device is displayed in a VT100 window, placed into a video buffer and sent to the AutoView
3100/3200 switch as though it came from a VGA target. Likewise, keystrokes entered on a
keyboard are sent to the attached device as though they were typed upon a VT100 terminal.
AVRIQ-SRL module modes
The following modes can be accessed from the AVRIQ-SRL module:
On-Line: This mode enables you to send and receive serial data.
Configuration: This mode enables you to specify AutoView 3100/3200 switch communication
parameters, the appearance of the Terminal Applications menu and key combinations for spe
-
cific actions and macros.
History: This mode enables you to review serial data.
Configuring the AVRIQ-SRL module
NOTE: The AVRIQ-SRL module is a DCE device and only supports VT100 terminal emulation.
Pressing Ctrl-F8 will activate the Configuration screen of the AVRIQ module’s Terminal
Applications menu, which enables you to configure your AVRIQ-SRL module.
NOTE: When any Terminal Applications menu is active, pressing Enter saves changes and returns you to the
previous screen. Pressing Escape returns you to the previous screen without saving changes.
Within the Terminal Applications menu’s Configuration screen, you can modify the
following
options:
Baud Rate: This option allows you to specify the serial port communications speed. Available
options are 300, 1200, 2400, 9600, 19,200, 34,800, 57,600 or 115,200 bps. The default value
is 9600.
Parity: This option allows you to specify the serial port’s communications parity. Available
options are EVEN, ODD or NONE. The default value is NONE.
Flow Control: This option allows you to specify the type of serial flow control. Available
options are NONE, XOn/XOff (software) and RTS/CTS (hardware). The default value
is NONE. If you select a bps rate of 115,200, the only available flow control is
RTS/CTS (hardware).
AutoView/CD Mode: This option allows you to control how the AutoView 3100/3200 switch
and CD lines operate. Available options are Always on and Toggle. When in Toggle mode,
AutoView and CD lines are turned off for one-half second and then turned on each time a mod
-
ule is selected or deselected. The default value is Always on.