8. Input
When Input locking is set to a specific input and there is no sync signal available, the locking will be switched
to Free run without changing the user settings. Once the sync is available, it applies again the user settings.
Options for Free Run
When free run is selected, radio button selected, then the Free Run Options become available.
Image 8-17
Free run options
Use the ▲ or ▼ key to select Fixed 60 H z or M anual and press ENTER to select.
Fixed60Hz:
locking is done on an internal sync of 60 Hz
Manual
locking is done on the indicated vertical frequency which can be changed by the user (between 24 Hz
and 60 Hz).
To change the locking frequency for Manual, use the ▲ or ▼ key to select Vert freq and press ENTER to activate.
Image 8-18
Free run, manual setting
Use the ▲ or ▼ key to change the value.
8.5 Minimum delay
Purpose
The minimum delay only affects the de-interlacing. In case of interlaced sources, the de-interlacer will be bypassed and the image
will be shown with line interpolation applied.
To ensure minimum delay in the other processing steps, make sure warping is OFF, the resolution of the input source is native and
the input locking is set to the main input.
How to toggle the delay
1. Press Menu to activate the menus and select Input → Minimum delay [On].
82
R5905032 HDX SERIES 02/03/2015