13. Input Source File Service
6. From the Edit file menu, select item OPTIONS. ()
7. Press ENTER (RCU) or the selection wheel to confirm.
The Edit File Options menu for that specific file appears on-screen and in the graphical display showing all the file parameters
which can be changed. (menu 13-14)
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with or
then <ENTER>
<EXIT> to return
0HQX
RANDOM ACCESS
ADJUSTMENT MODE
FILE SERVICE
IMAGE SETTINGS
PICTURE TUNING
GEOMETRY
PIP
Select with or
then <ENTER>
<EXIT> to return
0HQX
FILE SERVICE
LOAD
EDIT
RENAME
COPY
DELETE
OPTIONS
Select with or
then <ENTER>
<EXIT> to return
0HQX
EDIT FILE
F
ilename Src resolution
video625.s05 1 692x278i
video525.c01 1 675x240i
video525.c02 1 675x240i
-------------------------------
Active file : Video625.c05
Select with or
<ENTER> to accept
<EXIT> to return
0HQX
EDIT FILE video625.c05
HORIZONTAL
TOTAL 864 PIXELS
ACTIVE 692 PIXELS
START 130 PIXELS
PERIOD 64.000 µs
VERTICAL (FIELD)
TOTAL 313 LINES
ACTIVE 278 LINES
START 29 LINES
INTERLACED [ON]
READ AMDS
OPTIONS
, , , <ENTER>, <EXIT>
0HQX
EDIT FILE OPTIONS
Source number 6
Clamp position [leading]
Clamp delay 16
Clamp width 30
Field polarity [neg]
Field select [both]
Vertical refresh [sync]
Film Mode Detection [on]
Banner Protect [off]
Select with or
<ENTER>,, to change value
<EXIT> to return
0HQX
How to setup the different parameters
How to setup and the way to do it, please refer to the chapters File identification (File identification, page 53) and Changing the file
parameters (Changing the parameter settings, page 56).
13.5 Changing the parameter settings
Overview
Changing the parameter settings with the Remote Control
Changing the parameter settings with the selection wheel
13.5.1 Changing the parameter settings with the Remote Control
Saving changes to file
How to change the different parameters in the Edit mode is illustrated in the drawings below. After the necessary changes have
been applied, press EXIT key to return. A confirm edit file window is displayed allowing to ’confirm’, press <ENTER>, or to ’cancel’
,press<EXIT>, the applied changes.
CONFIRM
EDIT FILE
Save changes to file
’video625.c05’ ?
<ENTER> to confirm
<EXIT> to cancel
0HQX
Pixel and Line Values
1. Select item to be changed, using or cursor key, and follows instructions as indicated in drawings. (image 13-3, image 13-4,
image 13-5)
56
R5976519 ACSAR 12122002