Black Box TS1003A Barcode Reader User Manual


 
89
CHAPTER 5: Measurements
The pairs are displayed in the column on the left side, followed by the
PSEFLEXT in decibels (dB), the margin/limit, and the frequency. The result for
each pair is tagged with a PASS or FAIL indicator.
Press or to toggle between the PS ELFEXT results for
OMNIScanner and OMNIRemote.
Press (Graph) to display the PS ELFEXT graph for the currently
highlighted pair. PS ELFEXT is displayed for the frequency indicated by the cursor
position.
Press (Pairs) to view PS ELFEXT graphs for other pairs.
Press ESC to exit the POWER SUM ELFEXT screen.
5.3.11 P
OWER
S
UM
ACR
Power Sum ACR is calculated from the Attenuation of the disturbing pair
subtracted from the Power Sum NEXT for the pair. The worst case Power Sum
ACR is reported for each pair.