Bosch Appliances D6600 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
10 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.1.2 Ademco 4-1 Express (Message Type b)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
4-1 Express
Example
h b r r l s s s s s s a a a a s E s s s X t
Table 4: Message Type b (Ademco 4-1 Express) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
b
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-11 Spaces
Six spaces.
12-15 Account Number
Account number, four digits.
16 Space
One space.
17 E
Event Code, “A” as the default.
18-20 Spaces
Three spaces.
21 X
Zone number.
22 Trailer Character
Typically, this is HEX 14.
3.1.3 Ademco 4-2 Express (Message Type c)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
4-2 Express
Example
h c r r l s s s s s s a a a a s E s s X Y t
Table 5: Message Type c (Ademco 4-2 Express) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
c
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-11 Spaces
Six spaces.
12-15 Account Number
Account number, four digits.
16 Space
One space.
17 E
Event Code, “A” as the default.
18-19 Spaces
Two spaces.
20-21 XY
Event code and zone number.
22 Trailer Character
Typically, this is HEX 14.