Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
42 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.2.19 Seriee DTMF (Message Type l)
SIA Mode Description Seriee DTMF
Example
<LF><CRC><l><sequence#><receiver#><line#>[#aaaa|*data]<CR>
Table 70: Seriee DTMF (Message Type l) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
l (lowercase L).
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account #
The communicator's account number has four digits.
*
Data separator.
Data
DTMF Seriee Data.
3.2.20 Seriee FSK (Message Type k)
SIA Mode Description Seriee FSK
Example
<LF><CRC><k><sequence#><receiver#><line#>[#aaaaa|EZZ]<CR>
Table 71: Seriee FSK (Message Type k) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
k
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to
99. The receiver uses Line 0 (zero) for internal messages.
Account #
The communicator's account number has up to six digits.
E
Event code.
ZZ
Zone number.