3.2.26 Telim (Message Type n)
SIA Mode Description Telim Example
<LF><CRC><n><sequence#><receiver#><line#>[#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ]
<CR>
Table 81: Telim (Message Type n) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
n
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to
99. The receiver uses Line 0 (zero) for internal messages.
account #
The communicator's account number has up to six digits.
EETTZZZZZZZZZZZZZZZZ
ZZ
The event type and input line number.
3.2.27 Varitech FSK 4-1 (Message Type <TAB>)
SIA Mode Description Varitech FSK 4-1
Example
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaa|data]<CR>
Table 82: Varitech FSK 4-1 (Message Type <TAB>) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
<TAB>
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99
The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has four digits.
data
The event type and 1-digit zone number.