Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
36 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.2.11 DSC 4-3 (Message Type d)
SIA Mode Description DSC4-3 Example
<LF><CRC><d><sequence#><receiver#><line#>[#aaaa|XYY]<CR>
Table 53: DSC 4-3 (Message Type d) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
d
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
The communicator's account number has four digits.
X
Event code number.
YY
Zone number.
Figure 15: Message sent to printer
mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XY
Y+++sACCsaaaaseeeeeeeesiisnnn
For lines that are grouped, Gxx appears
instead of Lxx.
Table 54: DSC 4-3 (Message Type d) Printer
Output
Characters Description
DSG DSC/Sur-Gard 4-3 format.
Lxx: Line number.
Gxx Grouped line numbers.
Table 55: Event Code Table
Code Number Message Event
Characters
1 Alarm A
2 A
3 A
4 Close C
5 Open O
6 Alarm A
7 A
8 A
9 Restore R
0 Trouble T
B CloseGrp C
C OpenGrp O
D Bypass B
E UnBypass H
F Cancel O
Table 56: Printer Output Codes
Characters Description
ii ZN=Zone number - ID=User ID
nnn Zone/User number.
eeeeeeee Up to eight-character event type, right
justified – ALARM, RESTORE, TROUBLE,
OPEN, OPENGRP, CLOSE, CLOSEGRP,
BYPASS, UN BYPASS, CANCEL.