Bosch Appliances D6600 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 13
3.1.8 CFSK (Message Type i)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
CFSK Example
h i r r l s s s s a a a a a a T T E E s s t
Table 10: CFSK (Message Type i) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
i
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-9 Spaces
Four spaces.
10-15 Account Number
Six digit account number.
16-17 TT
Event Code.
18-19 EE
Zone/User ID.
20-21 Spaces
Two spaces.
22 Trailer Character
Typically, this is HEX 14.
3.1.9 Common Formats (Message Type 1)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Type 1 Example
h l r r l a a a a a a a a a a E E y y y y t
Table 11: Common Formats (Message Type 1) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
1
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line Number
Line number in the receiver gateway that sent the message.
6-15 Account Number
Account number, up to ten digits. Account numbers less than ten characters are right
aligned with leading ASCII spaces.
16-17 Event Code
Event codes define the type of signal received and interpreted by the D6500 receiver
gateway.
18-21 Zone Number
Zone or ID number sent by the communicator. Zone numbers less than four digits are
right aligned with leading ASCII spaces.
22 Trailer Character
Typically, this is HEX 14.
The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK,
Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option
selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode,
depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2
Messages on page 61 for a list of the messages and their descriptions.