Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 35
Undefined Messages
When a common format message contains unprintable hex characters (unprintable characters are out of ASCII
range 0x32-0x7E) or without an account block:
SIA Mode Description SIA Example
<LF><CRC><TAB><sequence#><receiver#><line#>[data]<CR>
Table 51: Common Formats (Message Type <TAB>) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical Redundancy Check number.
Message Type
09 hex.
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the
D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The D6600 uses Line 0 (zero) for receiver gateway messages.
Data
The receiver message contains hex characters either with or without account portion.
Figure 13: Message sent to printer
MM/DDsHH:MMsLxx[SIA]
+++ TEXT 1
+++ TEXT 2
3.2.10 DNIS/ANI (Message Type N)
SIA Mode Description SIA Example
<LF><CRC><N><sequence#><receiver#><line#>[#0000|Dddddddddddd&aaaaaaaaaa]
<CR>
Table 52: DNIS/ANI (Message Type N) Byte Description
Title Description
LF
Standard line feed character.
CRC
Cyclical redundancy check number.
Message Type
N
sequence#
The message sequence number. The valid sequence number range is 0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message. Valid digits are 00
to 99. The receiver uses Line 0 (zero) for internal messages.
account#
Fixed at 0000.
D
DNIS identified.
DNIS number (d)
DNIS number, up to 11 digits.
ANI identifier (&)
ANI identifier.
ANI number (a)
ANI number, up to 11 digit.s
Figure 14: Message sent to printer
MM/DDsHH:MMsLxxsDNISsddddddddddd+++sAN
Isaaaaaaaaaaa