Bosch Appliances D6600 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | 3.0 Computer Communication Protocols
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 27
3.1.29 VONK (Message Type V)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 VONK Example
h V r r l A A 1 2 3 4 5 6 7 8 9 A B C D E F G t
Table 34: VONK (Message Type V) Byte Description
# Title Description
1 Header Character
(h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
V
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6-7 Account Number
Two digit account number.
8-23 Zone status
Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is
Open, 1 to G appears in this position.
24 Trailer Character
Typically, HEX 14
3.1.30 X-SIA Text (Message Type S)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
h S r r l [ # a a a a | E M M Z Z Z Z * ` T
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
X-SIA Example
T T T T T T T T T T T T ‘ N M / * * * t
Table 35: X-SIA Text (Message Type S) Byte Description
# Title Description
1 Header Character
(h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
S
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group
Number
Line number in the receiver gateway that sent the message.
6 [
Open bracket.
7 #
#
8-11 Account Number
Use up to sixteen digits in the account number.
12 |
Separator. Indicates more data positions after account number.
13 E
SIA block code.
14-15 MM
SIA event code.
16-19 ZZZZ
Zone number.
20 *
Text identifier.
21
Quotation mark (single).
22-34 TT…T
13 character text string.
35
Qutotation mark (single).
36-37 NM
Unit field characters.
38 /
Separator.
39-41 ***
Next block of data.
42 Trailer Character
Typically, HEX 14.