Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
84 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
279.
Fail to Execute
(Door
Unlocked-
Interlock)
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ACC aaaa DOOR UNLOCKED-INTERLOCK
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasNsD35t
<header>[#aaaa|NriaaDKpppp]
280.
Fail To
Execute
(Door
Unlocked-
Door Secured)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa DOOR UNLOCKED-DOOR SECURED
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasNsD35t
<header>[#aaaa|NriaDKppp]
281.
Fail To
Execute
(Door
Unlocked-
Door Secured)
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ACC aaaa DOOR UNLOCKED-DOOR SECURE
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasNsD35t
<header>[#aaaa|NriaaDKpppp]
282.
Fail To
Execute
(Door
Unlocked-
Door Secured)
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ACC aaaa DOOR CYCLED-DOOR SECURED
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaADppppt
<header>[#aaaa|NriaaDKpppp]
283.
Fail To
Execute
(Door
Unlocked-
Door Secured)
(points < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ACC aaaa DOOR CYCLED-DOOR SECURE
+++ACC aaaa AREA=aa POINT=ppp
h1rrlssssssaaaasNsD35t
<header>[#aaaa|NriaDKppp]
284.
Fail To
Execute
(Door Cycled-
Interlock)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa DOOR CYCLED-INTERLOCK
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaADspppt
<header>[#aaaa|NriaDKppp]
285.
Fail To
Execute
(Door Cycled-
Interlock)
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ACC aaaa DOOR CYCLED-INTERLOCK
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaaADppppt
<header>[#aaaa|NriaaDKpppp]
286.
Fail To
Execute
(Door Cycled-
Door Secured)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa DOOR CYCLED-DOOR SECURED
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaaADspppt
<header>[#aaaa|NriaDKppp]
287.
Fail To
Execute
(SDI Device,
Incorrect
Response)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa INCORRECT RESPONSE
+++ ACC aaaa SDI=ddd
h1rrlssssssaaaasNsD34t
<header>[#aaaa|NpidddYX]
288.
Fail To
Execute
(SDI Device,
No Response)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa NO RESPONSE
+++ ACC aaaa SDI=ddd
h1rrlssssssaaaasNsD34t
<header>[#aaaa|NpidddYX]
289.
Fail To Open
by Area
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO OPEN
+++ ACC aaaa AREA=a
h1rrlssssssaaaasTsssEt
<header>[#aaaa|NriaOI]
The AREA in the
second line of the
report was not
disarmed during the
programmed opening
time window.