52 Bosch Security Systems, Inc. | 1/07 | 4998122703-01
3.3 Input Command Processing
Input devices, such as automation systems, send the
commands described in Table 88 to the receiver. If
the receiver does not recognize a command, it
generates a REJECT COMMAND message, prints at
connected printers, and sends an ASCII text
message to the automation port.
The CPU programming in Menu Item
2.2.4 of the D6600/D6100 Receiver must
be set to 1 to use input commands.
Table 88: ASCII Text Message to Automation
Port
The automation system, or other device,
sends the command shown below to set the
time at the D6600/D6100 if the
D6600/D6100 is programmed to
synchronize the time and date with the
automation system.
D6650
Mode:
!Thhmm<CR>
Set Time
SIA
Mode:
<seq><rec><line>[CSThhm
m]<CR>
hh - hours (24 hour format)
mm – minutes.
The automation system, or other device,
sends the command shown below to set the
date at the D6600/D6100 if the
D6600/D6100 is programmed to
synchronize the time and date with the
automation system.
D6650
Mode:
!Dmmddyy<CR>
Set Date
SIA
Mode:
<seq><rec><line>[CSDmmd
dyy]<CR>
mm - month, dd - day, yy – year
The automation system, or other device,
sends the command shown below to stop a
two way audio session on the line specified.
D6650
Mode:
!Kn<CR>
Stop Two
Way
Audio
SIA
Mode:
<seq><rec><line>[CLKnn]
<CR>
nn - line card number, 01-32.
D6650
Mode:
h3rrlsREJECTsCOMMANDsst
Reject
Command
SIA
Mode:
<LF><CRC><TAB><sequence
#><receiver#><line#>[RE
JECT COMMAND]<CR>
Table 89 shows the D6500 and SIA automation
output formats for these input commands.
Table 89: Input Command Output Messages
D6500 Mode SIA Mode Printer Output
Set
Time
h1rrssssss
ssssssXss2
t
[NJT] TIME SET
Set
Date
h1rrssssss
ssssssXss5
1t
[NJD] DATE SET
Stop
Two
Way
Audio
h1rrssssss
ssssssXss5
2t
[CLK] TWO WAY
AUDIO STOP
STOP