Bosch Appliances D6600 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 117
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
655.
SDI Restoral
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa RESTORAL ZN D
h1rrlssssssaaaasRsssDt
<header>[#aaaa|NURD]
Zonex restoral
message: indicates a
trouble condition on
the wiring from the
POPEX Module to the
POPITs was cleared.
Wiring connecting the
control panel and
keypads restored. Point
bus, supervised
keypad, printer, or
other serial device was
restored.
2.
656.
SDI Restoral
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL
+++ ACC aaaa SDI=ddd
h1rrlssssssaaaasRsssDt
<header>[#aaaa|NpidddER]
The supervised
keypad, printer, or
other serial device
listed in the second
line of the report was
restored.
657.
SDI Restoral
(Point
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL
+++ ACC aaaa POINT=ppp SDI=ddd
h1rrlssssssaaaasRspppt
<header>[#aaaa|NpidddERppp]
The supervised
keypad, printer, or
other serial device
listed in the second
line of the report was
restored.
658.
Sensor Reset
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ ACC aaaa AREA=a ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nria/idiiiXIrrr]
The sensor specified in
the second line of the
report (labeled
“RELAY”) located in
the specified AREA
was reset by a user
with the ID shown.
1,
7,
8.
659.
Sensor Reset
(ID not
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ ACC aaaa AREA=a RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|NriaXIrrr]
The sensor specified in
the second line of the
report (labeled
“RELAY”) located in
the specified AREA
was reset by a user
with the ID shown.
1,
7,
8 ,
D7112
660.
Sensor Reset
(ID/relay not
reported)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ ACC aaaa AREA=a
h1rrlssssssaaaasNsD27t
<header>[#aaaa|NriaXI]
The sensor specified in
the second line of the
report (labeled
“RELAY”) located in
the specified AREA
was reset by a user
with the ID shown.
1,
7,
8 ,
D7112
661.
Sensor Reset
(relay > 254,
user < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=aa ID=iii RELAY#=rrrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nriaa/idiiiXIrrrr]
662.
Sensor Reset
(relay > 254,
user >254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=a ID=iiii RELAY#=rrrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nria/idiiiiXIrrrr]
663.
Sensor Reset
(relay < 255,
user < 255)
(OMNI)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa SENSOR RESET
+++ACC aaaa AREA=aa ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD27t
<header>[#aaaa|Nria/idiiiXIrrr]