Bosch Appliances D6600 Network Router User Manual


 
Conettix D6600/D6100 | Computer Interface Manual | Appendix C: Modem IIIa2 Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01 83
Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
267.
Extend Close
Time by Area
(users < 255)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME
+++ACC aaaa AREA=a ID=iiii TIME=hh:mm
h1rrlssssssaaaasTsD26t
<header>[#aaaa|Nriaa/idiiii/tihhmmCE]
268.
Extend Close
Time by Area
(users > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME
+++ACC aaaa AREA=aa ID=iiii TIME=hh:mm
h1rrlssssssaaaasTsD26t
<header>[#aaaa|Nriaa/idiiii/tihhmmCE]
269.
Extra Point
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTRA POINT
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasTspppt
<header>[#aaaa|NriaXEppp]
270.
Extra Point
(points > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTRA POINT
+++ACC aaaa AREA=aa POINT=pppp
h1rrlssssssaaaasTppppt
<header>[#aaaa|NriaaXEpppp]
271.
Extra RF Point
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTRA RF POINT
+++ACC aaaa SDI=ddd
h1rrlssssssaaaasTsD16t
<header>[#aaaa|NpidddXF]
272.
Extra RF Point
Detected
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa EXTRA RF POINT
h1rrlssssssaaaasTsD16t
<header>[#aaaa|NriaXF]
An extra RF POINT in
the AREA in the
second line of the
report was detected.
1,
D7112
273.
Fail To Call
RAM
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN F
h1rrlssssssaaaasTsssFt
<header>[#aaaa|NBTF]
Abnormal RAM
session termination or
beginning of the
Command 58 Fire
Test.
2.
274.
Fail To Call
RAM
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM
h1rrlssssssaaaasTsF02t
<header>[#aaaa|NRA]
Control panel
attempted to call RAM
and was unsuccessful.
275.
Fail To Close
by Area
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO CLOSE
+++ ACC aaaa AREA=a
h1rrlssssssaaaasTsssEt
<header>[#aaaa|NriaCI]
The AREA in the
second line of the
report was not armed
before the
programmed closing
time.
276.
Fail To Close
by Area
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO CLOSE
+++ ACC aaaa AREA=a
h1rrlssssssaaaasTsssEt
<header>[#aaaa|NriaCI]
The AREA in the
second line of the
report was not armed
before the
programmed closing
time.
277.
Fail To Close,
Delinquent
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa DELNQNT CLOSING
+++ACC aaaa AREA=a
h1rrlssssssaaaasTsssEt
<header>[#aaaa|NriaCD]
278.
Fail To
Execute
(Door
Unlocked-
Interlock)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE
+++ ACC aaaa DOOR UNLOCKED-INTERLOCK
+++ ACC aaaa AREA=a POINT=ppp
h1rrlssssssaaaasNsD35t
<header>[#aaaa|NriaDKppp]