Table 92: Modem IIIa
2
Messages (continued)
Event Device/Mode Display Explanation Refer to Section
C.1 Zonex and
Comex
Translation on
page 137.
585.
Relay Set
(by USER)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ ACC aaaa BY USER
+++ ACC aaaa ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD28t
<header>[#aaaa|NidiiiRCrrr]
The RELAY specified
in the second line of
the report was set.
586.
Relay Set
(relay <255,
user > 254) (by
USER)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY USER
+++ACC aaaa ID=iiii RELAY#=rrr
h1rrlssssssaaaasNsD28t
<header>[#aaaa|NidiiiiRCrrr]
587.
Relay Set
(relay > 254)
(by
Programmer)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY PROGRAMMER
+++ACC aaaa RELAY#=rrrr SDI=ddd
h1rrlssssssaaaasNsD21t
<header>[#aaaa|NpidddRCrrrr]
588.
Relay Set
(relay > 254)
(by RAM)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY REMOTE
+++ACC aaaa RELAY#=rrrr
h1rrlssssssaaaasNsD23t
<header>[#aaaa|NRCrrrr]
589.
Relay Set
(relay > 254)
(by SKED)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY SKED
+++ACC aaaa RELAY#=rrrr SKED=kkk
h1rrlssssssaaaasNsD19t
<header>[#aaaa|NaikkkRCrrrr]
590.
Relay Set
(relay >254,
user < 255) (by
USER)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY USER
+++ACC aaaa ID=iii RELAY#=rrrr
h1rrlssssssaaaasNsD28t
<header>[#aaaa|NidiiiRCrrrr]
591.
Relay Set
(relay >254,
user > 254) (by
USER)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ACC aaaa BY USER
+++ACC aaaa ID=iii RELAY#=rrrr
h1rrlssssssaaaasNsD28t
<header>[#aaaa|NidiiiRCrrrr]
592.
Relay Set by
Sked
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ ACC aaaa RELAY#=rrr SKED=kk
h1rrlssssssaaaasNsD19t
<header>[#aaaa|NaikkRCrrr]
The RELAY specified
in the second line of
the report was set.
7,
D9112
593.
Relay Set by
User
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RELAY SET
+++ ACC aaaa ID=iii RELAY#=rrr
h1rrlssssssaaaasNsD28t
<header>[#aaaa|NidiiiRCrrr]
The RELAY specified
in the second line of
the report was set.
1,
7,
D9112
594.
Remote
Bypass
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS
+++ ACC aaaa AREA=a POINT=ppp PHONE#=h
h1rrlssssssaaaasNspppt
<header>[#aaaa|Nria/phhUBppp]
The POINT in the
AREA specified in the
second line of the
report is faulted, and
was bypassed by a
RAM through through
the specified phone
line.
1,
D9112
595.
Remote
Bypass
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z
h1rrlssssssaaaasTssszt
<header>[#aaaa|NBTz]
9,
D9112
596.
Remote
Bypass
(Call back)
(point > 254)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa RAM BYPASS
+++ACC aaaa AREA=aa POINT=pppp PH#=hh
h1rrlssssssaaaasNppppt
<header>[#aaaa|Nriaa/phhhUBpppp]