3.1.4 Ademco Contact-ID (Message Type a)
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Contact ID
Example
h a r r l s a a a a 1 8 Q X Y Z G G C C C t
Table 6: Message Type a (Ademco Contact ID) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
a
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6 Space
One space.
7-10 Account Number
Account number, four digits.
11-12 18
Ademco Contact-ID format number
13 Qualifier
Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event.
14-16 XYZ
Class code and event code (see Appendix A).
17-18 GG
Group number.
19-21 CCC
Zone codes or user ID.
22 Trailer Character
Typically, this is HEX 14.
3.1.5 Ademco High Speed, 4-8-1 (Message Type f)
SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request
D6500 Byte Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
High Speed
Example
h f r r l a a a a a a s C C C C s C C C C s C t
Table 7: Message Type f (Ademco High Speed, 4-8-1) Byte Description
# Title Description
1 Header Character (h)
Optional. Check with the computer automation software for compatibility.
2 Message Type
f
3-4 Receiver Number
Receiver gateway number from 01 to 99.
5 Line/Group Number
Line number in the receiver gateway that sent the message.
6-11 Account Number
Account number, up to six digits.
Account number less than six characters is right aligned with leading ASCII spaces.
12 Space
One space.
13-16 CCCC
Channels 1 to 4.
17 Space
One space.
18-21 CCCC
Channels 5 to 8.
22 Space
One space.
23 C
Supervisory channel.
24 Trailer Character
Typically, this is HEX 14.