Cabletron Systems 04-0053-01 Switch User Manual


 
9-8 SmartSwitch ATM User Guide
Events and Alarms Troubleshooting
Note Depending on the activity of your ATM SmartSwitch, the appearance of events on
the ATM SmartSwitch may be too frequent to use the console comfortably. It is
recommended that you turn on the automatic display of events only when
troubleshooting.
Use the
show alarms command to view a list of the currently logged alarms. For example,
SmartSwitch # show alarms
Index(ALL) :
0 33554702 000:07:05:300
---------------------------------------------------
pvcm_cac_admit: failed 501037
1 33554652 023:56:23:317
---------------------------------------------------
LECS Operational
2 117506049 024:01:54:083
---------------------------------------------------
Failed to re-establish SAAL connection
Port ID 0x01c81000
T309 10000
3 117506049 024:01:54:430
---------------------------------------------------
More(<space>/q)?:
Alarms are displayed in the following format:
Alarm number — The index number of the alarm in the circular buffer
Alarm ID — A unique ID assigned to the alarm
Time — Time of alarm, in switch up-time in hours, minutes, seconds, and milliseconds
Object — The object affected by the alarm (port, LEC, and so on)
Alarm messages can be automatically displayed on the ATM SmartSwitch console. Use the
set alarmdisplay
command to display alarms on the console as they occur:
SmartSwitch # set alarmdisplay
alarmDisplay(OFF) : on
SmartSwitch #
9.5.3 Deleting Events and Alarms
To delete events or alarms currently logged within your ATM SmartSwitch, use the delete events and delete alarms
commands, respectively.