Cabletron Systems 6H122-16 Switch User Manual


 
Chapter 5: Local Management
5-28 6H122-16 User’s Guide
5.9.1 Configuring the Trap Table
To configure the Trap table, proceed as follows:
1. Using the arrow keys, highlight the appropriate Trap Destination
field.
2. Enter the IP Address of the workstation that is to receive traps. IP
address entries must follow the DDN format.
For example: 134.141.79.121
3. Press ENTER. If an invalid entry is entered “INVALID IP
ENTERED” is displayed in the Event Message Line.
4. Using the arrow keys, highlight the Trap Community Name field.
Enter the community name.
5. Press ENTER.
6. Using the arrow keys, highlight the Enable Traps field. Press the
SPACE bar to choose either YES (send alarms from the chassis to the
workstation), or NO (prevent alarms from being sent).
7. Using the arrow keys, highlight the SAVE command and press
ENTER. The message “SAVED OK” displays on the screen.
The designated workstations now receive traps from the 6C105.
NOTE
Exiting without saving causes a “NOT SAVED?” message to
appear. Edits will be lost if they are not saved before exiting.