Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
106
Command ID 46
Command
Name
Monitor Magnification Setting
A3 (A9)
Data Magnification : N (×2
N
)
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation Magnification is specified by an exponent of the power-of-two.
E.g.
Data = -2 2
-2
= 0.25 times
Data = -1 2
-1
= 0.5 times
Data = 0 2
0
= 1 times
Data = 1 2
1
= 2 times
Data = 2 2
2
= 4 times
(See 5.2. , “Analog Monitor Output Selecting”)
Related
Command
Command ID 47
Command
Name
Monitor Magnification Setting
A4 (A10)
Data Magnification : N (×2
N
)
Return
Value
0: Command execution successful
1: Command execution unsuccessful
Explanation Magnification is specified by an exponent of the power-of-two.
E.g.
Data = -2 2
-2
= 0.25 times
Data = -1 2
-1
= 0.5 times
Data = 0 2
0
= 1 times
Data = 1 2
1
= 2 times
Data = 2 2
2
= 4 times
(See 5.2. , “Analog Monitor Output Selecting”)
Related
Command
Command ID 48
Command
Name
Monitor Magnification Check
Data 0: A2, A8 monitor magnification
1: A3, A9 monitor magnification
2: A4, A10 monitor magnification
Return
Value
Magnification : N (×2
N
)
Explanation The exponent of power-of-two.
(See 5.2. , “Analog Monitor Output Selecting”)