Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
37
2.8.5. RS-232C Communication Command Input and High-Speed Communication
Switching
A position command input can be switched with a RS-232C communication command.
Command ID Data
23
0: RS-232C command communication
7: High-speed serial communication
Note: In the case of two axis control, it is necessary to execute this command for each axis.
It is possible to receive input of RS-232C communication commands even when switching to
high-speed serial communication. However, as position commands give priority to the input of
high-speed serial communication, operation commands such as RS-232C communication command
step movement, and raster scans will be ignored.
Command ID = 23 Data 7
A1C023/7
A2C023/7
Command ID = 23 Data 0
A1C023/0
A2C023/0
High-speed serial
communication
RS-232C command
communication
*Command also sent to Axis 2
*Command also sent to Axis 2