Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
115
Parameter ID 17
Parameter
Name
#1 Digital Notch Filter Q
Data Q value of the first digital notch filter (Unit: ×100)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the Q value of the first digital notch filter.
Set a value multiplied by 100.
Related
Command
/Parameter
#1 Notch Filter Frequency (Parameter ID = 16)
#1 Notch Filter Depth (Parameter ID = 18)
Parameter ID 18
Parameter
Name
#1 Digital Notch Filter Depth
Data Depth of the first digital notch filter (Unit: dB)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the depth of the first digital notch filter.
Related
Command
/Parameter
#1 Notch Filter Frequency (Parameter ID = 16)
#1 Notch Filter Q (Parameter ID = 17)
Parameter ID 19
Parameter
Name
#2 Digital Notch Filter Frequency
Data Central frequency of the second digital notch filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the central frequency of the second digital notch filter.
Related
Command
/Parameter
#2 Notch Filter Q (Parameter ID = 17)
#2 Notch Filter Depth (Parameter ID = 18)