Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
116
Parameter ID 20
Parameter
Name
#2 Digital Notch Filter Q
Data Second digital notch filter Q value (Unit: ×100)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the Q value of the second digital notch filter.
Set a value multiplied by 100.
Related
Command
/Parameter
#2 Notch Filter Frequency (Parameter ID = 16)
#2 Notch Filter Depth (Parameter ID = 18)
Parameter ID 21
Parameter
Name
#2 Digital Notch Filter Depth
Data Depth of the second digital notch filter (Unit: dB)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the depth of the second digital notch filter.
Related
Command
/Parameter
#2 Notch Filter Frequency (Parameter ID = 16)
#2 Notch Filter Q Value (Parameter ID = 17)
Parameter ID 22
Parameter
Name
Low-pass Filter Cutoff Frequency
Data Cutoff frequency of the digital low-pass filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the cutoff frequency of the digital low-pass filter.
Related
Command
/Parameter