Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
118
Parameter ID 26
Parameter
Name
Cycle Time of Raster Scan
Data Scan Time (Unit: See Explanation.)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This command is used to set the raster scan time (operation by command).
The scan time is the set value × 10 μs.
E.g. For the interval of 100 ms, set 10000 (10000 × 10 μs = 100 ms).
Related
Command
/Parameter
Duty of Raster Scan (Parameter ID = 27)
Scan Angle of Raster Scan (Parameter ID = 28)
Interval Time of Raster Scan (Parameter ID = 30)
Start Position of Raster Scan (Parameter ID = 31)
Parameter ID 27
Parameter
Name
Duty of Raster Scan
Data Raster scan duty ratio (Unit: %)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the duty ratio of raster scan (operation by command).
(See Explanation of Parameter ID = 26.)
Related
Command
/Parameter
Cycle Time of Raster Scan (Parameter ID = 26)
Scan Angle of Raster Scan (Parameter ID = 28)
Interval Time of Raster Scan (Parameter ID = 30)
Start Position of Raster Scan (Parameter ID = 31)
CW
CCW
Scan Angle 
(+)
0
Raster Scan Time
Scan Angle 
(-)
CW
CCW
Scan Angle 
(+)
0
Raster Scan Time
Scan Angle 
(-)